Sport Polygonal high masts with stationary service area (VMON)

OrderGeneral information
Fill out the feedback form and our managers will contact you

    • * - required field

    Lighting of sports facilities. etc.  

    Poles are manufactured of steel sheets by bending with one, two or three longitudinal welds.  

    The pole consists of two or more sections with the upper flange where a platform for installation of lighting fixtures is installed.

    Poles of the following types are manufactured:

    • with a ladder, equipped with a ladder with a railing and flood light platform;
    • without a ladder – not with a ladder with a railing and maintained from a truck-mounted hydraulic lift;
    • with a ladder without railing with a safety rope.

    Protected from corrosion by hot galvanizing (ISO 1461).
    This type of coating is not decorative, but only functional.
    Corrosion resistance warranty is 25 years.  


    High mast with a stationary crown VMON is a complicated technical item.
    VMON masts have both standard versions designed for standard operating conditions and individual versions which take into account special climatic conditions and order requirements.

    Specifications

    ModelHeight*, H, mWeight**, kgBottom diameter, D, mmFlange diameter, A, mmHole center-to-center, B, mmNumber of sectionsб pcs
    VMON-1616m555 - 1103 kg400 - 785mm580 - 820mm490 - 720mm2
    VMON-2020m827 - 2132 kg525 - 850mm750 - 1130mm650 - 1020mm2
    VMON-2525m1570 - 2660 kg480 - 770mm700 - 1095mm600 - 960mm3
    VMON-3030m2420 - 3990 kg770 - 870mm1000 - 113mm890 - 1020mm3
    VMON-3535m2835 - 7517 kg820 - 1145mm1100 - 1400mm990 - 1270mm4
    VMON-4040m2987 - 6380 kg860 - 1270mm1100 - 1530mm990 - 1400mm4
    VMON-4545m5780 kg1000mm1300mm1150mm4
    VMON-5050m6780 - 8785 kg1150 - 1250mm1450 - 1500mm1290 - 1370mm4

    ! The plant reserves the right to make design changes that do not affect the quality and technical characteristics of the product

    !! The weight of the product shown in the table is calculated. Deviation of the actual weight from the calculated one is allowed